Next: Specifications of downcomer flow Up: Input for the hydraulics Previous: Riser specifications   Contents   Index

Steam separator specifications

We have utilized data which correspond to the Peach Bottom and Dresden-2 forced circulation BWRs found in the NATBWR report [41, p. A-3]. The data should be representative for steam separators in forced circulation BWRs and since the SBWR is based on forced circulation BWR technology it seems reasonable to use these data.

The separator data are given by


\begin{eqnarray*}
D_{\mbox{\protect\scriptsize e,separator}} &=& 0.154 {\mbox{ ...
...x{ m}}^2 \\
K_{\mbox{\protect\scriptsize separator}} &=& 3.1
\end{eqnarray*}


$\textstyle \parbox{1.50cm}{\begin{eqnarray}
\end{eqnarray}}$

The separator carry under and carry over fractions, CU and CO [--], are taken as [41, p. A-7]


\begin{eqnarray*}
CU &=& 0.002 \\
CO &=& 0.001
\end{eqnarray*}


$\textstyle \parbox{1.50cm}{\begin{eqnarray}
\end{eqnarray}}$

 
 

 
 
Revision 2.0, Copyright © 1999-2004 Jakob Christensen